Installation Instructions

Environment
DN9913471 © Nokia Corporation Draft 19 (44)
Issue 3-0 en Nokia Proprietary and Confidential
2.3.3 Mechanical conditions for operation
In respect to mechanical conditions during operation, the Nokia MetroSite EDGE
Base Station complies with ETS 300 019-1-4:1992 class 4.1.
2.3.4 Ingress protection
The electronic components inside the units of the Nokia MetroSite EDGE Base
Station are protected against the ingress of rain, snow and dust to the minimum
level of IP55 of European standard EN 60529, and level 3R of UL standard 50.
2.3.5 Acoustic noise
The maximum acoustic noise generated by the Nokia MetroSite EDGE Base
Station is 61 dBA. The acoustic noise is measured according to ISO 3744. The
noise type is sound power.
2.3.6 EMC shielding
The chassis and the units of the Nokia MetroSite EDGE Base Station together
provide the electromagnetic compatibility (EMC) shielding. The EMC shielding
complies with the standards listed in Nokia MetroSite EDGE Base Station:
Product Description.
2.3.7 Safety
The MetroSite BTS cabinet fulfils the relevant safety requirements: EN 60215,
EN 60950 and UL 1950.
For more specific information refer to Nokia MetroSite EDGE Base Station:
Product Description.