Installation Instructions
Table Of Contents
- Requirements for Installation and Operation
- 1 About this document
- 2 Environment
- 3 Installation requirements
- 4 Cabinet interfaces and cables
- 5 Installation equipment
Environment
DN9913471 © Nokia Corporation Draft 17 (44)
Issue 3-0 en Nokia Proprietary and Confidential
Note
2.2.3 Mechanical conditions for transportation
In respect to mechanical conditions during transportation, the Nokia MetroSite
EDGE Base Station complies with ETS 300 019 1-2:1992 class 2.3.
2.3 Operation
This section defines the environmental conditions which are possible during the
operation of the Nokia MetroSite EDGE Base Station at locations which are not
protected from direct weather influences.
When surveying the prospective sites, consider the values presented in this
section.
Operating conditions are defined as stationary: the equipment is mounted on a
structure or mounting device, or it is permanently placed at a site. The Nokia
MetroSite EDGE Base Station is not intended for portable use.
2.3.1 International standard for operation
According to the standard ETS 300 019-1-4:1992, the class for Nokia MetroSite
EDGE Base Station equipment is class 4.1.
2.3.2 Climatic conditions for operation
In respect to climatic conditions during operation, the Nokia MetroSite EDGE
Base Station complies principally with class 4.1, as presented in Table 3.
However, for the temperature and humidity values, the table presents extended
operational climatic conditions, which differ from class 4.1. The weather
shielding of the Nokia MetroSite EDGE Base Station is valid when the BTS is
mounted in the recommended positions.