Product Info

Commissioning
54 (78) © Nokia Corporation Draft DN999099
Nokia Proprietary and Confidential Issue 4-0 en
Note
6. If the type of the transmission unit is FXC E1/T1, check or modify the
settings for the other line interfaces as described in Steps 1 - 5.
7. Click OK to accept the changes.
Figure 23. LIF Settings with the FXC E1/T1 interface unit
7.1.2 LIF settings for F(X)C RRI transmission units
Define RRI LIF settings as follows:
1. Select the tabbed page for the line interface you want (Flexbus 1, Flexbus
2, or Platform Interface).
If the transmission unit type is FC RRI (no cross-connection capability), the
dialogue box has only two tabbed pages: Flexbus 1 and Platform Interface.
2. Tick the ‘In Use’ option.
3. Select the ‘Capacity’ option for the interface (2, 4, 8, or 16 x 2 MB).