DN00112232 © Nokia Corporation Draft 25 (26)
Issue 3-0 en Nokia Proprietary and Confidential
Note
Note
When alarm 7620 is active, it will not be sent to Nokia BTS Manager. However,
alarm cancelling can be seen on Nokia BTS Manager.
In case of alarm 7620, if the power loss is very short and the power is on again
within 1500 ms, the alarm is cancelled automatically. No actions required.
Table 16. 7620 INCOMING POWER LOST
7620 INCOMING POWER LOST
Severity: Object affected: Object state: Unit:
* BCF Enabled HVSx
Fault reason: Instruction: Alarm cancelling:
No fault reason text with
the alarm.
Base station power
supply unit has lost its
main power.
1. Check the mains supply.
2. If the mains supply is OK, replace the power
supply unit.
Automatic.
Table 17. 7621 INTOLERABLE CONDITIONS ON SITE
7621 INTOLERABLE CONDITIONS ON SITE
Severity: Object affected: Object state: Unit:
* BCF Enabled WTxx, HVTx
Fault reason: Instruction: Alarm cancelling:
Temperature inside the TRX
is dangerously high.
1. Check that the fan unit is operating.
2. If the fan unit is OK, ensure that the
environment of the base station site meets the
conditions specified for Nokia MetroSite EDGE
Base Station.
Automatic.