Product Info

Alarm Descriptions
24 (26) © Nokia Corporation Draft DN00112232
Nokia Proprietary and Confidential Issue 3-0 en
Table 13. 7615 RTS IN TEST USE
7615 RTS IN TEST USE
Severity: Object affected: Object state: Unit:
* RTS Disabled WTxx, HVTx
Fault reason: Instruction: Alarm cancelling:
No fault reason text with the
alarm.
Internal O&M SW is testing
the timeslots during TRX
test.
1. No actions required. Automatic.
Table 14. 7616 OSCILLATOR ADJUSTMENT TEMPORARILY
INTERRUPTED
7616 OSCILLATOR ADJUSTMENT TEMPORARILY INTERRUPTED
Severity: Object affected: Object state: Unit:
* BCF Enabled VIFA
Fault reason: Instruction: Alarm cancelling:
Oven oscillator
adjustment function
interrupted.
1. Check the Abis connection.
2. If the Abis connection is OK, replace the faulty VIFA
unit.
Automatic.
Table 15. 7617 SEVERAL CALLS DROPPED DUE PROBLEM WITH
TRANSCODER
7617 SEVERAL CALLS DROPPED DUE PROBLEM WITH TRANSCODER
Severity: Object affected: Object state: Unit:
** TRX Enabled WTxx, HVTx
Fault reason: Instruction: Alarm cancelling:
Other faults.
There is an error with the
connection between the
base station and the
transcoder.
1. Check the transmission path between the base
station and the transcoder.
Automatic/Manual.