Product Info
Table Of Contents
BTS alarm descriptions
DN00112232 © Nokia Corporation Draft 23 (26)
Issue 3-0 en Nokia Proprietary and Confidential
Note
In case of alarm 7606, if a BCCH TRX is affected, the BSC performs a BCCH
reconfiguration if possible.
Table 11. 7607 TRX OPERATION DEGRADED
7607 TRX OPERATION DEGRADED
Severity: Object affected: Object state: Unit:
** TRX Enabled WTxx, HVTx
Fault reason: Instruction: Alarm cancelling:
Other faults. 1. Replace the faulty TRX. Automatic.
Table 12. 7609 TRE FAULTY
7609 TRE FAULTY
Severity: Object affected: Object state: Unit:
*** BCF Disabled VXxx
Fault reason: Instruction: Alarm cancelling:
Master TRX detected that
connection to transmission
unit is lost.
1. If the alarm is seen at the BSC, the transmission
unit is not working properly. However, if the base
station otherwise operates properly, there is no
need for immediate repair. The transmission
alarms are not reported to the BSC.
2. If the alarm is seen on Nokia BTS Manager only,
the transmission unit is not operating. Reset the
BCF.
3. If the alarm reappears after BCF reset, switch
the cabinet power off and on.
4. If the alarm reappears after the recovery actions
above, replace the faulty transmission plug-in
unit.
Manual/Automatic.