Product Info

Attachments
DN99252966 © Nokia Corporation Draft 65 (66)
Issue 3-0 en Nokia Proprietary and Confidential
Instructions:
1. Strip the power feeder cable from its main insulation 'X' mm (TBA).
2. Strip the inner conductors and cut them so that they are of equal length.
3. Strip each wire insulation to 'Y' mm (TBA) length using a sharp blade,
taking care not to cut any strands of wire.
4. Insert each wire, in turn, into a contact and using the crimping tool, crimp
the contact around the wire.
5. Undo the cable clamp to enable the cable to be inserted.
6. Push the contacts into the connector in their correct positions.It is very
important that the contacts are in the correct order in the connector.
7. If the cable is to connect the DC supply to a MetroSite BTS, the procedure
is to be repeated for the other end of the cable. If the cable is to connect the
DC supply to a MetroHub, refer to the MetroHub User Manual
(Installation)for the connection of the other end of the cable.