Product Info

Accessories and specifications
DN99252966 © Nokia Corporation Draft 55 (66)
Issue 3-0 en Nokia Proprietary and Confidential
2.8.3 AC power cables for MetroSite BTS or MetroHub
The power cables for AC connectivity are light and flexible. They can be installed
in dry, damp and wet environments, both indoor and outdoor, in addition to fire-
sensitive locations.
The cables have three conductors made of high quality tinned copper insulated
with EPDM-rubber and are 10 m in length.
One end of the cable is fitted with an IEC320 three-pin male connector and the
other end with an appropriate three-pin male connector for connection to the
mains power source (user defined).
230 VAC power cable: CS72452.50
Minimum recommended handling
temperature
-50
o
C
Minimum recommended bending radius
(single bend)
22 mm
Colour Yellow-green
Table 31. Grounding cable specifications (Continued)
Code Details
Table 32. Specifications for the 230 VAC power cable
Code Detail
Cross section
1.5 mm
2
Nominal diameter 9.0 mm
Nominal voltage U
o
/U 300 V/500 V
Maximum continuous operating temperature
+60
o
C
Minimum recommended handling temperature
-50
o
C
Minimum bending radius 54 mm
Live wire colour Brown
Neutral wire colour Blue
Earthing cable colour Green-yellow
Sheath colour Black