User's Manual

Nokia MetroSite Base Station Commissioning
30 (34) © Nokia Telecommunications Oy Internal Copy NTC DN999099
Confidential Issue 1 en DRAFT 3 Draft
Note
3. Open the Add Cross-Connection dialog box by right-clicking the mouse
and selecting the Add... command. (Another way to open the dialog box is
to choose the Add command on the Cross-connections | Connections
submenu.)
4. Define the following settings according to the cross-connection plan:
label, i.e. the name of the new cross-connection (max. 80 characters)
cross-connection type; in this case the type is ‘bi-directional’
granularity (with nx64k set also its coefficient n)
cross-connection class
timeout.
5. Click the Tx1/Rx1 button to open the Termination Point view.
6. In the Interface tree view, select one of the FXC transmission card’s
interfaces, e.g. Interface 1.
In the timeslot table, the earlier reserved timeslots and bits are indicated by grey,
while the selected ones will become yellow.
7. Click a cell in the table to define the start bit of the frame.
8. Click OK. The dialog box is closed.
9. Click the Tx2/Rx2 button to open the Termination Point view.
10. In the Interface tree view, select an interface, e.g. Interface 2.
11. Click a cell in the table to define the start bit of the frame.
12. Click OK. The dialog box is closed.
13. Click Apply in the Add Cross-connection dialog box. All settings are
loaded but the window remains open.
14. Repeat steps 1 - 13 for other types of cross-connections.
15. Activate the bank by selecting the Cross-connections | Banks | Activate
command and click OK.
16. Close the views and the Cross-connection tool.