User's Manual

Commissioning
NTC DN999099 © Nokia Telecommunications Oy Internal Copy 17 (34)
Issue 1 en DRAFT 3 DraftConfidential
Note
9. Click the Traffic Manager button to open the Traffic Manager dialog box.
The Next button is disabled until you return from the Traffic Manager.
Figure 6. Traffic Manager button
10. Allocate transmission capacity to the BTS with the Traffic Manager (refer
to 3.2) and, when completed, click OK. This will establish a transmission
connection between the BTS and the BSC. (In case the connection fails,
refer to chapter 5, Troubleshooting and fault reporting.)
When you click OK in the Traffic Manager, the Transmission
Configuration page reappears. The Back button is disabled, because the
transmission parameters have already been sent to the BTS. If you need to
change any parameters you have specified prior to this point, you have to
run the Undo Commissioning procedure first and then re-commission the
BTS.
When the Transmission Configuration page reappears, there is a short
delay before the Wizard automatically proceeds to the next page. If the
BTS Test Reporting page does not appear automatically, click Next to
proceed.
When the BTS Test Reporting page appears, there is a slight delay before the
automatic BSC-controlled tests start. If you click the Manual button to open the
TRX Test dialog box and the BSC-controlled tests start, the dialog box closes
automatically.