Local GPS Cabling Installation Chapter 4: Access P oint Hardw are Installation
Procedure 4 -9 Procedure to Install Surge Arrestor (Continued)
Crimp one end each of a 6 – 8 inch long, #6 A WG cable to the lug nuts.
5
Unscrew knurled nut from surge arrestor and attach ground lug.
Screw knurled nut into surge arrestor and hand tighten.
A ttach other end of ground cable to the threaded ground
connection just above the surge arrestor . See Figure 4-13 .
A ttach self locking nut to secure ground connection to B CU .
Figure 4 -12 Surge Arrestor
ti-cdma-05829.eps
TO
RGPS OR RFGPS
CONNECT OR
ANTENNA CONNECT OR
GROUND CONNECT OR
RGPS / RFGPS SURGE ARREST OR
800 - 2500 MHz
4 -28 68P09277A59 -8