User's Manual

Access P oint Hardw are Installation RF Head DC P ower Cabling Installation
RF Head DC Power Cabling Installation
Objective
This section contains the procedure for installing the RF Head DC power cables.
DC Cable Description
Cable G listed in T able 3 -1 is required for installation
Tools Required
The following tools are required to install the DC P ower cables.
DC Power Cable Installation
F ollow the steps in Procedure 4 -5 to install the DC P ower Cables.
Procedure 4 -5 Procedure to Install DC P ower Cables
1
If not already open, open the B CU Customer Interface compartment.
2
Before routing DC power cable, verify that it is properly color coded. If more
than one RF Head in use, ensure that they are all properly color coded.
Color coded labels and tie-wraps can be found on the
compartment side of the door of the B CU Customer Interface
compartment.Tie-wraps should be attached near the connnector .
3
Connect the DC power cables to connector RFU1 RFU4, as required.
4
Route the DC P ower cables through conduit up to the tower . Bundle and
secure the cables (if RF Head is not present) or connect to the appropriate
RF Head.
68P09277A59 -5 4 -25