Access P oint Hardw are Installation Manual RF Head Installation Procedures
Procedure A -1 Procedure to Install RF Head Main Support Br ack et Assembly
1
Remove nuts and plate (or washers) from both ends of the U -bolt.
2
Set Main Support Bracket Assembly at the required height.
It is recommended that two people perform attach the bracket
to the pole.
3
Slide first U -bolt around pole and through top slots of Main
Support Bracket Assembly . Slide plate (or washers) over threads.
Thread nuts on U -bolt and hand tighten.
4
Slide second U -bolt around pole and through bottom slots of Main
Support Bracket Assembly . Slide plate (or washers) over threads.
Thread nuts on U -bolt and hand tighten.
5
Align Main Support Bracket Assembly on pole facing the appropriate
direction and tighten nuts using a socket wrench or power driver . T orque
nuts to 45 in-lbs (5 N-m).
Installing the RF Head
F ollow the steps in Procedure A -2 to install the RF Head.
Procedure A -2 Procedure to Install the RF Head
1
Place the RF Head on a flat surface, large finned-side down.
2
A ttach the left and right side mounting brackets
to RF Head using a T30 T orx screw driver .
The brackets straight edges face away from Main Support Bracket Assembly .
3
If the optional filter is being used, proceed
to Procedure A-3 to attach it to the RF Head.
Otherwise, proceed with step 4
4
A ttach solar shield to side brackets by snapping the tabs on the bottom of the
shield into side bracket slots. Refer to Figure A-3 .
5
Lift shield and drop over the top of the RF Head.
Handle of RF Head slips through slot in solar shield.
Tighten two captive screws on solar shield to secure it to side mounting
bracket. T orque captive screws to 45 in-lbs (8.2 N-m)
6
Set the RF Head so that it is resting on the side brackets support arms and
RF Head bottom (filter if attached).
68P09277A59 -5 A -5
OCT 2006 Draft