User's Manual
Access P oint Hardw are Installation Manual RF Head Installation Procedures
Tools and Materials
• Mounting Bracket Assembly
• U -bolts
• Set of metric sockets (3/8–in or 1/4–in)
• Set of standard sockets (3/8–in or 1/4–in)
• 3/8–in or 1/4–in driver
• T orque Driver
• Cordless P ower Driver
• Ground Lug
• Crimp T ool
• T30 T orx Screw Driver
• Adjustable Crescent W rench
U -Bolt Specications
Reference Figure A -1 and T able A -2 to determine the proper U -bolt to use.
Figure A -1 U -Bolt Sizing
Table A -2 DAP U -Bolt Sizing
Nominal
Pipe Size
Pipe OD
Minimum Dimension B
Minimum Dimension C
(in) (in) (mm) (in) (mm) (in) (mm)
2 2.067 52.50 3.886 98.70 0.6 15
2.5 2.469 62.71 4.429 112.50 0.6 15
3 3.068 77.93 5.098 129.50 0.6 15
Increasing dimension B beyond that indicated above will result in a corresponding increase in dimension C
in order to maintain proper clamping force
RF Head Mounting Bracket Assembly Installation
Figure A -2 shows the Mounting Bracket Assembly for the RF Head.
68P09277A59 -5 A -3