User's Manual
Fiber Optic Cabling Installation Chapter 4: Access P oint Hardw are Installation
Fiber Optic Cabling Installation
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■
■
Objective
This section contains the procedure for installing the fiber optic cables.
Cable Description
Cable H as listed in T able 3 -1 is required for installation.
The minimum bend radius for this cable is 90 mm.
Procedure 4 -9 Procedure to Install Fiber Optic Cables
1
Before routing the Fiber Optic cable up the
tower , verify that is properly color coded.
Red — RF Head 1
Blue — RF Head 2
Y ellow — RF Head 3
Green — RF Head 4
Color coded labels and tie-wraps can be found on the compartment
side of the door of the B CU Customer Interface compartment.
2
Connect the Fiber Optic cables to the bulkhead feedthroughs (FIBER) on the
underside of the B CU .
3
Route the cable(s) up the tower(s), bundle and secure to tower (if
RF Head is not present) or connect to the appropriate RF Head.
Use tie-wraps or appropriate clamps to secure cable to tower .
4 -38 68P09277A59 -5
Draft OCT 2006