User's Manual
Div ersit y Access P oint (DAP) RF Head Assembly Installation Chapter 4: Access P oint Hardw are Installation
Figure 4 -4 U -Bolt Sizing
ti-cdma-05727.eps
C
B
Table 4 -3 DAP U -Bolt Sizing
Pipe OD
Minimum Dimension B
Minimum Dimension C
(in) (mm) (in) (mm) (in) (mm)
2.067 52.50 3.886 98.70 0.6 15
2.469 62.71 4.429 112.50 0.6 15
3.068 77.93 5.098 129.50 0.6 15
Increasing dimension B beyond that indicated above will result in a corresponding increase
in dimension C in order to maintain proper clamping force
RF Head Assembly Installation Procedure
F ollow the steps in Procedure A -1 to install the RF Head Assembly including main Support
Bracket Assembly .
The following procedure is based on the RF Head arriving already assembled. If the
RF head must be assembled at the site then follow the procedure in Appendix A.