Product Info
Table Of Contents
- 13.1_IHET6HG1_install_manual.pdf
- Install_Manual_PRELIMINARY
- R20 1X UBS Macro BTS Hardware Installation
- Copyrights
- Contents
- List of Figures
- List of Table
- About This Manual
- Front Matter
- Chapter 1 - Introduction and Frame Identification
- Abbreviations and Acronyms
- Overview
- Scope of manual
- Prerequisites
- Chapter 1 - Introduction and frame identification
- Chapter 2 – UBS Macro BTS installation procedure
- Chapter 3 - Low-to-Mid Capacity Frame Expansion Procedures
- Chapter 4 - What’s next
- Equipment shipped assembled
- Equipment shipped un-assembled
- Follow the task sequence
- Follow the site plan
- Site cleanliness
- Site manager
- Color coding
- Rack vs. frame
- Required documentation
- Equipment may vary from figures
- Item identification
- UBS Macro BTS frames
- Figure 1-1 UBS Macro BTS low-tier/low-capacity frame (1000 mm ra
- Figure 1-2 Low capacity UBS Macro BTS starter frame (1800 mm rac
- Figure 1-3 UBS Macro BTS mid-capacity frame (1800 mm rack)
- Figure 1-4 High capacity 800 MHz UBS Macro BTS fully expanded fr
- Figure 1-5 High-capacity 1.9 GHz UBS Macro BTS fully expanded fr
- Items to be installed
- UBS Macro BTS frames
- Tools and materials
- Unpacking Instructions
- Chapter 2 - UBS Macro BTS Installation Procedure
Cable list, diagr ams and connectors Chapter 2: UBS Macro B T S Installation Procedure
Table 2 -3 UBS Macro B T S external I/O cable run list (Continued)
From T o
Reference
(used in
manual)
Part number
Item
Connector
Item
Connector
Notes
None
Customer Sector 2
IDRF
RX DIV
(N-type,
coaxial)
Sector 2
RX Div .
Ant. Cable
N-type,
coaxial
RF Ant.,
50-Ohm
Coaxial
(Note 2)
None
Customer Sector 3
IDRF
RX DIV
(N-type,
coaxial)
Sector 3
RX Div .
Ant. Cable
N-type,
coaxial
RF Ant.,
50-Ohm
Coaxial
(Note 2)
1. Cables 3086039H10 through H14 are various lengths; where the part number suffix
indicates the following cable lengths: H10 = 15 m (50 ft), H11 = 38 m (125 ft), H12 =
76 m (250 ft), H13 =152 m (500 ft) and H14 = 304 m (1000 ft). Cables H10 and H11
are included in Motorola option T472AG and T472AH, respectively . Cables H12, H13
and H14 are included in Motorola option T472AJ , T472AK and T472AL respectively .
2. Cable may be connected to a lightning arrester .
Connector locations
Figure 2 -1 through Figure 2 -4 show the items that external cables connect to . F or each
connector , the name is stated and where the associated cable goes.
IDRF I/O details
Figure 2 -1 shows connector locations and usage for the 800 MHz IDRF .
Figure 2 -2 shows connector locations and usage for the 1.9 GHz IDRF .
2 -6 68P09283A62 -2
PRELIMINARY A UG 2007