Installation Instructions

Adding an Optional RX Splitter Chapter 3: Low -to -Mid Capacit y Fr ame Expansion Procedures
Procedure 3 -5 Adding an RX splitter to the XMI shelf (Continued)
2
While working at the front of the UBS Macro BTS frame, pick up the RX
splitter and mount it onto the bottom of the XMI shelf as follows:
See Figure 3-5 Mounting the RX splitter on page 3- 18 .
P osition the RX splitter as follows:
RX splitter I/O connectors facing toward front of the frame.
RX splitter mounting tabs, one on each end of splitter , facing up.
In front of the XMI shelf bottom bracket.
Align the guide pins on each RX splitter mounting tab with the
corresponding hole located on the XMI shelf bottom bracket (see
photograph A ).
Insert the guide pins into the holes and hold the RX splitter mounting
tabs against the XMI shelf bottom bracket.
Insert a mounting screw through each RX splitter mounting tab and into
the XMI shelf bottom bracket. (see photograph B ).
3
Using a T25 TORX driver , tighten the mounting screws to 4.8 N-m (42.25
in-lb) ±10%.
Procedural reference diagram
The following diagram helps clarify certain steps in Procedure 3 -5 .
Figure 3 -5 Mounting the RX splitter
ti-cdma-06036.eps
A B
3 -18 68P09283A62 -2
PRELIMINARY A UG 2007