User's Manual

Bay Level Offset Calibration – continued
FEB 2005 1X SC 4812T Lite BTS Optimization/ATP 3-117
PRELIMINARY
Example:
C[1]=384
(Odd Cal Entry)
C[2]=19102 (Even Cal Entry)
C[3]=777 (Odd Cal Entry)
C[4]=19086 (Even Cal Entry)
C[19]=777 (Odd Cal Entry)
C[20]=19086 (Even Cal Entry)
.
.
.
= 1 “Calibration Point”
= 1 “Calibration Point”
= 1 “Calibration Point”
In the example above, BLO was measured at only two frequencies
(Channels 384 and 777) for SCCP BBX–1 Slot Transmit (Table 3-38).
The BLO Data for the highest frequency measured (Channel 777) will
be written to the remaining eight Transmit Calibration Points (defined
by Entry C[5] through Entry C[20]) for BBX–1.
Slot Block Temperature Compensation – Each BBX Slot Block also
has a Temperature Compensation Data Section (TempLevelCal) where
Power Level Compensation Factors for Temperature Variations are
stored..
CAL File and BLO Data Download
When BLO Data is downloaded to the BBX Cards after Calibration, the
data is downloaded to the devices in the order it is stored in the CAL
File. TX Calibration Data (Entries C[1] through C[60]) are sent first.
Data for the ten BBX Slot 1 Calibration Points (Entries C[1] through
C[20]) are sent initially, followed by data for the ten BBX Slot 2
Calibration Points (Entries C[21] through C[40]), and so on. The RX
Calibration Data is sent next in BBX Slot Sequence, followed by the RX
Diversity Calibration Data.
Test Equipment Set–up for
RF Path Calibration
Perform the procedure in Table 3-39 and refer as needed to Figure 3-16
or Figure 3-17 to Set–up Test Equipment.
Table 3-39: Set–up Test Equipment for RF Path Calibration Procedure
n Step Action
1 If it has not already been done, refer to the procedure in Table 3-6 (on Page 3-18) to interface the
LMF Computer Terminal to the BTS Frame LAN A Connector.
2 If it has not already been done, refer to Table 3-10 (on Page 3-29) to start a GUI LMF Session.
3 If required, calibrate the Test Equipment per the procedure in Table 1-4.
table continued on next page