User's Manual
Test Set Calibration – continued
FEB 2005 1X SC 4812T Lite BTS Optimization/ATP 3-101
PRELIMINARY
Table 3-29: Selecting Test Equipment Manually in the Serial Connection Tab Procedure
n ActionStep
4
Type the GPIB Address in the corresponding GPIB Address Box.
– Refer to the Setting GPIB Addresses section of Appendix F for directions on verifying and/or
changing Test Equipment GPIB Addresses.
Motorola–recommended addresses are:
– 1 = Signal Generator
– 13 = Power Meter
– 18 = Communications System Analyzer
NOTE
When Test Equipment Items are manually selected by the operator, the LMF defaults to using a
Power Meter for RF Power Measurements. The LMF will use a Communications System
Analyzer for RF Power Measurements only if a Power Meter is not selected (Power Meter Check
Box not checked).
5 Click on Apply.
– The button will darken until the selection has been recorded.
NOTE
With Manual Selection, the LMF does not attempt to detect the Test Equipment to verify it is
connected and communicating with the LMF.
6 Click on Dismiss to close the LMF Options Window.