User's Manual

Test Set Calibration – continued
3-100 1X SC 4812T Lite BTS Optimization/ATP FEB 2005
PRELIMINARY
Prerequisites
Ensure that the following have been completed before selecting Test
Equipment:
S Test Equipment is turned on.
S GPIB Addresses set in the Test Equipment have been verified as
correct using the applicable procedures in Appendix F. (Not required
with Agilent E7495A.)
S LMF Computer Serial Port and Test Equipment are connected to the
GPIB Box. (GPIB not applicable with Agilent E7495A)
Selecting Test Equipment
Test Equipment may be selected either manually with operator input or
automatically using the LMF autodetect feature.
Manually Selecting Test
Equipment in a Serial
Connection Tab
Test Equipment can be manually specified before or after the Test
Equipment is connected. The LMF does not attempt to verify that the
Test Equipment is actually detected when Manual Selection is specified.
Perform the procedure in Table 3-29 to manually select Test Equipment.
Table 3-29: Selecting Test Equipment Manually in the Serial Connection Tab Procedure
n Step Action
1 In the LMF Window Menu Bar, click Tools and select Options... from the Pull–down Menu.
The LMF Options Window appears.
If it is not in the forefront, click on the Serial Connection Tab.
2 Select the correct Serial Port in the COMM Port: Pick List (normally COM1).
If it is not selected (no black dot showing), click on the Manual Specification Button.
3 Click on the Check Box(es) corresponding to the Test Equipment Item(s) to be used.
table continued on next page