Test Set Calibration – continued
FEB 2005 1X SC 4812T Lite BTS Optimization/ATP 3-99
PRELIMINARY
Manual Calibration Procedures
Agilent E4406A Transmitter Tester
The E4406A does not support the Power Level Zeroing Calibration
performed by the LMF. If this instrument is to be used for Bay Level
Offset Calibration and Calibration is attempted with the LMF Calibrate
Test Equipment Function, the LMF will return a Failure Message
Status Window stating that Zeroing Power is not supported by the
E4406A.
– Refer to the Equipment Calibration section of Appendix F for
instructions on using the instrument’s Self–alignment (Calibration)
Function prior to performing Bay Level Offset Calibration..
Power Meters
Manual Power Meter Calibration Procedures to be performed prior to
automated Calibration are included in the Equipment Calibration section
of Appendix F..
Cable Calibration
Manual Cables using the HP 8921A and Advantest R3465
Communications System Analyzers are provided in the Manual Cable
Calibration section of Appendix F, if needed..
GPIB Addresses
GPIB Addresses can range from 1 through 30. The LMF will accept any
address in that range, but the numbers entered in the LMF Options
Window GPIB Address Boxes (Table 3-29 and Table 3-30) must match
the addresses set in the Test Equipment. Motorola recommends using 1
for a CDMA Signal Generator, 13 for a Power Meter, and 18 for a
Communications System Analyzer. To verify and, if necessary, change
the GPIB Addresses of the Test Equipment, refer to the Setting GPIB
Addresses section of Appendix F.
IP Addresses
For the Agilent E7495A Communications Test Set, set the IP Address
and complete Initial Set–up as described in Appendix F. Specifically, see
Table F-1 on Page F-1.
Selecting Test Equipment
Serial Connection and Network Connection Tabs are provided in the
LMF Options Window to specify the Test Equipment Connection
Method.
– The Serial Connection Tab is used when the Test Equipment Items
are connected directly to the LMF Computer through a GPIB Box
(normal set–up).
– The Network Connection Tab is used when the Test Equipment is
to be connected remotely via a Network Connection or the Agilent
E7495A Communications Test Set is used. Refer to Appendix F.
Specifically, see Table F-1 on Page F-1.