User's Manual

Test Set Calibration
3-98 1X SC 4812T Lite BTS Optimization/ATP FEB 2005
PRELIMINARY
Test Equipment Calibration
Background
Proper Test Equipment Calibration helps to ensure accurate BTS
Optimization and Acceptance Testing by assuring that the Test
Equipment and associated cables do not introduce Measurement Errors.
If the Test Equipment Set being used to optimize or test the
BTS has been calibrated and maintained as a set, this
procedure does not need to be performed.
NOTE
This procedure must be performed prior to beginning the Optimization.
Verify that all Test Equipment (including all associated cables and
adapters actually used to interconnect Test Equipment Items and the
BTS) has been calibrated and maintained as a set.
If any piece of Test Equipment, Test Cable, or RF Adapter
that makes up the calibrated Test Equipment Set has been
replaced, the set must be re-calibrated.
Failure to do so can introduce Measurement Errors,
resulting in incorrect measurements and degradation
to system performance.
Motorola recommends repeating Cable Calibration
before testing at each BTS Site.
CAUTION
Calibration of the Communications System Analyzer (or
equivalent Test Equipment) must be performed at the site
before calibrating the overall Test Equipment Set.
Calibrate the Test Equipment after it has been
allowed to warm–up and stabilize for a a minimum of
60 minutes.
NOTE
Automatic Calibration
Procedure
Procedures included in this section use the LMF Automated Calibration
Procedure to determine Path Losses of the supported Communications
Analyzer, Power Meter, associated Test Cables, Adapters, and (if used)
Antenna Switch that make up the overall calibrated Test Equipment Set.
After Calibration, the Gain/Loss Offset Values are stored in a Test
Measurement Offset File on the LMF Computer.
3