User's Manual
Test Equipment Set-up – continued
FEB 2005 1X SC 4812T Lite BTS Optimization/ATP 3-79
PRELIMINARY
IS–95A/B Operation
Optimization and ATP Testing for IS–95A/B Sites and Carriers may be
performed using the following Test Equipment:
S CyberTest
S Advantest R3267 Spectrum Analyzer with R3562 Signal Generator
S Advantest R3465 Spectrum Analyzer with R3561L Signal Generator
and HP–437B or Gigatronics Power Meter
S Agilent E4406A Transmitter Test Set with E4432B Signal Generator
S Agilent 8935 Series E6380A Communications Test Set (formerly HP
8935)
S Hewlett–Packard HP 8921 (with CDMA Interface and, for 1.9 GHz,
PCS Interface) and HP–437B or Gigatronics Power Meter
S Spectrum Analyzer (HP8594E) – optional
S Rubidium Standard Timebase – optional
CDMA2000 1X Operation
Optimization and ATP Testing for CDMA2000 1X Sites and Carriers
may be performed using the following Test Equipment:
S Advantest R3267 Spectrum Analyzer with R3562 Signal Generator
S Agilent E4406A Transmitter Test Set with E4432B Signal Generator
S Agilent 8935 Series E6380A Communications Test Set (formerly HP
8935) with Option 200 or R2K and with E4432B Signal Generator for
1X FER
S Agilent E7495A Communications Test Set
Test Equipment Preparation
See Appendix F for specific steps to prepare each type of Test Set and
Power Meter to perform Calibration and ATP.
Agilent E7495A Communications Test Set requires additional set–up
and preparation. This is described in detail in Appendix F.
Test Equipment Connection
Charts
To use the following charts to identify necessary Test Equipment
Connections, locate the Communications System Analyzer being used in
the COMMUNICATIONS SYSTEM ANALYZER Columns, and read
down the column. Where a dot appears in the column, connect one end
of the Test Cable to that Connector. Follow the horizontal line to locate
the end connection(s), reading up the column to identify the appropriate
Test Equipment and/or BTS Connector.
3