User's Manual

Test Equipment Set-up
3-78 1X SC 4812T Lite BTS Optimization/ATP FEB 2005
PRELIMINARY
Connecting Test Equipment to
the BTS
The following types of Test Equipment are required to perform
Calibration and ATP Tests:
S LMF
S Communications System Analyzer Model supported by the LMF
S Power Meter Model supported by the LMF (required when using the
HP 8921A/600 and Advantest R3465 Analyzers)
S Non–radiating Transmit Line Termination Load
S Directional Coupler and In–line Attenuator
S RF Cables and Adapters
Refer to Table 3-27 for an overview of Test Equipment Connections for
currently supported by the LMF. In addition, see the following figures:
S Figure 3-31, Figure 3-32, and Figure 3-33 show the Test Set
Connections for TX Calibration
S Figure 3-35 through Figure 3-40 show the Test Set Connections for
Optimization/ATP Tests
Test Equipment GPIB Address
Settings
All Test Equipment is controlled by the LMF through an
IEEE–488/GPIB Bus. To communicate on the Bus, each piece of Test
Equipment must have a GPIB Address Set that the LMF will recognize.
The Standard Address Settings used by the LMF for the various types of
Test Equipment Items are as follows:
S Signal Generator Address: 1
S Power Meter Address: 13
S Communications System Analyzer Address: 18
Using the procedures included in the Verifying and Setting GPIB
Addresses section of Appendix F, verify and, if necessary, change the
GPIB Address of each piece of employed Test Equipment to match the
applicable addresses above.
Supported Test Equipment
To prevent damage to the Test Equipment, all Transmit
(TX) Test Connections must be through a 30 dB
Directional Coupler plus a 20dB In-line Attenuator for
both the 800 MHz and 1.9 GHz BTSs.
CAUTION