User's Manual

Using the LMF – continued
FEB 2005 1X SC 4812T Lite BTS Optimization/ATP 3-35
PRELIMINARY
Table 3-14: Establishing MMI Communication Procedure
n ActionStep
2 If the LMF Computer has only one Serial Port (COM1) and the LMF is running, disconnect the
LMF from COM1 by performing the following actions.
2a Click on Tools in the LMF Window Menu Bar, and select Options from the Pull–down Menu.
An LMF Options Dialog Box will appear.
2b In the LMF Options Dialog Box, click the Disconnect Port Button on the Serial Connection Tab.
3 Start the named HyperTerminal Connection for MMI Sessions by double clicking on its Windows
Desktop Shortcut.
NOTE
If a Windows Desktop Shortcut was not created for the MMI Connection, access the connection
from the Windows Start Menu by selecting:
Programs > Accessories > Hyperterminal > HyperTerminal > <Named HyperTerminal
Connection (e.g., MMI Session)>
4 Once the MMI Connection Window opens, establish MMI Communication with the BTS FRU by
pressing the LMF Computer <Enter>Key until the prompt identified in the applicable procedure
is obtained.
NULL MODEM
BOARD
(TRN9666A)
8–PIN TO 10–PIN
RS–232 CABLE
(P/N 30–09786R01)
RS–232 CABLE
8–PIN
LMF
COMPUTER
To FRU MMI Port
DB9–TO–DB25
ADAPTER
COM1
OR
COM2
FW00687
Figure 3-9: LMF Computer Common MMI Connections
Online Help
Task oriented Online Help is available in the LMF by clicking Help in
the Window Menu Bar, and selecting LMF Help from the Pull–down
Menu.