3-34 1X SC 4812T Lite BTS Optimization/ATP FEB 2005
PRELIMINARY
Logging Out of a BTS from the CLI Environment
Perform the procedure in Table 3-13 to logout of a BTS when using the
CLI Environment.
Table 3-13: BTS CLI Logout Procedure
n Step Action
NOTE
If the BTS is also logged into from a GUI running at the same time and further work must be done
with it in the GUI, proceed to Step 1.
1 Log out of a BTS by entering the following command:
logout bts–<bts#>
– A system response similar to the following will be displayed:
LMF>
13:24:51.028 Command Received and Accepted
COMMAND=logout bts–33
13:24:51.028 Command In Progress
13:24:52.04 Command Successfully Completed
REASON_CODE=”No Reason”
2 If desired, close the CLI Interface by entering the following command:
exit
– A response similar to the following will be displayed before the window closes:
Killing background processes....
Establishing an MMI
Communication Session
Equipment Connection
Figure 3-9 illustrates common equipment connections for the LMF
Computer. For specific connection locations on FRUs, refer to the
illustration accompanying the procedures that require the MMI
Communication Session..
Initiate MMI Communication
For those procedures that require MMI Communication between the
LMF and BTS FRUs, perform the procedures in Table 3-14 to initiate
the Communication Session..
Table 3-14: Establishing MMI Communication Procedure
n Step Action
1 Connect the LMF Computer to the equipment as detailed in the applicable procedure that requires
the MMI Communication Session.
table continued on next page