User's Manual

Alarms Testing – continued
3-148 1X SC 4812T Lite BTS Optimization/ATP FEB 2005
PRELIMINARY
Table 3-54: CDI Alarm Input Verification Procedure (without the Alarms Test Box)
n ActionStep
23 Refer to Figure 3-46 and sequentially short the ALARM B Connector CDI 19 through CDI 36
pins (25–26 through 59–60) together.
No alarms should be displayed.
24 Load data to the MGLI to reset the Alarm Relay Conditions according to the CDF File.
Pin and Signal Information for
Alarm Connectors
Table 3-55 lists the Pins and Signal Names for Alarms A and B.
Table 3-55: Pin and Signal Information for Alarm Connectors
ALARM A ALARM B
Pin Signal Name Pin Signal Name Pin Signal Name Pin Signal Name
1 A CDO1 NC 31 Cust Retn 4 1 B CDO9 NC 31 B CDI 22
2 A CDO1 Com 32 A CDI 4 2 B CDO9 Com 32 Cust Retn 22
3 A CDO1 NO 33 Cust Retn 5 3 B CDO9 NO 33 B CDI 23
4 A CDO2 NC 34 A CDI 5 4 B CDO10 NC 34 Cust Retn 23
5 A CDO2 Com 35 Cust Retn 6 5 B CDO10 Com 35 B CDI 24
6 A CDO2 NO 36 A CDI 6 6 B CDO10 NO 36 Cust Retn 24
7 A CDO3 NC 37 Cust Retn 7 7 B CDO11 NC 37 B CDI 25
8 A CDO3 Com 38 A CDI 7 8 B CDO11 Com 38 Cust Retn 25
9 A CDO3 NO 39 Cust Retn 8 9 B CDO11 NO 39 B CDI 26
10 A CDO4 NC 40 A CDI 8 10 B CDO12 NC 40 Cust Retn 26
11 A CDO4 Com 41 Cust Retn 9 11 B CDO12 Com 41 B CDI 27
12 A CDO4 NO 42 A CDI 9 12 B CDO12 NO 42 Cust Retn 27
13 A CDO5 NC 43
Power Supply
Modules Alarm
Return
13 B CDO13 NC 43 B CDI 28
14 A CDO5 Com 44
Power Supply
Modules Alarm
14 B CDO13 Com 44 Cust Retn 28
15 A CDO5 NO 45 Cust Retn 11 15 B CDO13 NO 45 B CDI 29
16 A CDO6 NC 46 A CDI 11 16 B CDO14 NC 46 Cust Retn 29
17 A CDO6 Com 47 Cust Retn 12 17 B CDO14 Com 47 B CDI 30
18 A CDO6 NO 48 A CDI 12 18 B CDO14 NO 48 Cust Retn 30
table continued next page
3