Troubleshooting: Span Control Link – continued
6-46 1X SC 4812T Lite BTS Optimization/ATP FEB 2005
PRELIMINARY
Table 6-48: Set BTS Span Parameter Configuration Procedure
n ActionStep
7 If the Span Equalization must be changed, enter the following MMI Command:
config ni equal <cr>
The terminal will display a response similar to the following:
COMMAND SYNTAX: config ni equal Span equal
Next available options:
LIST – Span : Span
a : Span A
b : Span B
c : Span C
d : Span D
e : Span E
f : Span F
>
8 At the Entry Prompt (>), enter the designator from the list for the Span to be changed as shown in
the following example:
> a <cr>
The terminal will display a response similar to the following:
COMMAND SYNTAX: config ni equal a equal
Next available options:
LIST – equal : Span Equalization
0 : 0–131 feet (default for T1/J1)
1 : 132–262 feet
2 : 263–393 feet
3 : 394–524 feet
4 : 525–655 feet
5 : LONG HAUL
6 : 75 OHM
7 : 120 OHM (default for E1)
>
9 At the Entry Prompt (>), enter the code for the required equalization from the list as shown in the
following example:
> 0 <cr>
The terminal will display a response similar to the following:
> 0
The value has been programmed. It will take effect after the next reset.
GLI3>
10 Repeat Step 7 through Step 9 for each in–use Span.
table continued on next page