User's Manual

Table Of Contents
Troubleshooting: Receive ATP
6-20 1X SC 4812T Lite BTS Optimization/ATP FEB 2005
PRELIMINARY
Multi–FER Test Failure
Table 6-19: Multi-FER Failure Troubleshooting Procedure
n Step Action
1 Verify that the Test Equipment is configured correctly for an FER Test.
2 Verify that the Test Equipment is locked to the 19.6608 MHz and Even Second Clocks.
On the HP 8921 Analyzer, the yellow LED (REF UNLOCK) must be OFF.
3 Verify MCC Cards have been loaded with data and are INS_ACTIVE.
4 Disable and re-enable the MCC (one or more based on the extent of the failure).
5 Disable, re-load code and data, and re-enable the MCC (one or more MCC Cards based on extent
of failure).
6 Verify that the Antenna Connections to the frame are correct based on the LMF Directions
Messages.
6