Troubleshooting: Calibration
6-12 1X SC 4812T Lite BTS Optimization/ATP FEB 2005
PRELIMINARY
Bay Level Offset Calibration
Failure
Table 6-12: BLO Calibration Failure Troubleshooting Procedure
n Step Action
1 Verify that the Power Meter or Communications System Analyzer is configured correctly.
Refer to the Test Equipment Set–up section of Chapter 3, and is connected to the proper BTS
TX Antenna Connector.
2 If a Power Meter is being used, perform the following actions.
2a Re-calibrate the Power Meter and verify it is calibrated correctly with Cal Factors from the Power
Sensor.
Refer to Appendix F.
2b Verify that the Power Sensor is functioning properly by checking it with the 1–mW (0 dBm)
Power Ref Signal.
2c Verify communication between the LMF and Power Meter is working by checking that the Meter
Display is showing RES :
3 Verify that the parameters in the bts–#.cdf File are set correctly for the BTS Operating Band as
follows:
For 1900 MHz:
Bandclass = 1; Freq_Band = 16
For 800 MHz:
Bandclass = 0; Freq_Band = 8
4 Verify that no LPA on the carrier is in Alarm State (rapidly flashing red LED).
If any LPAs are in Alarm State, proceed to Step 5.
NOTE
Under normal conditions, only two green LEDs are ‘ON’ (Power and Ready).
5 Reset the LPA(s) by pulling the applicable circuit breaker on the DC PDA.
6 After 5 seconds, push the circuit breaker back in.
7 Verify that the GPIB Adapter is not locked up.
If any other LED is continuously ‘ON’, proceed to Step 8.
8 Power-cycle (turn power off and on) the GPIB Box and retry the procedure.
6