Troubleshooting: Download – continued
6-10 1X SC 4812T Lite BTS Optimization/ATP FEB 2005
PRELIMINARY
Cannot Download DATA to Any
Device (Card)
Table 6-9: Data Download Failure Troubleshooting Procedure
n Step Action
1 Re-seat the card and repeat the Code and Data Load Procedure.
2 Verify that the ROM and RAM Code Loads are of the same release by statusing the card.
Refer to Download the BTS section of Chapter 3 for more information.
Cannot ENABLE Device
Before a device can be enabled (placed in service), it must be in the
OOS_RAM State (yellow in LMF Display) with data downloaded to the
device. The color of the device on the LMF changes to green once it is
enabled.
The four Device States that can be displayed by the LMF are:
S ENABLED (bright green, INS_ACT)
S STANDBY (olive green, INS_STANDBY – Mate CSM and GLI only)
S DISABLED (yellow, OOS_RAM)
S RESET (blue, OOS_ROM)
Table 6-10: Device Enable (INS) Failure Troubleshooting Procedure
n Step Action
1 Re-seat the card and repeat the Code and Data Load Procedure.
2 If the CSM cannot be enabled, verify that the CDF has correct latitude and longitude data for the
Cell Site location and GPS Sync.
3 Verify that the Primary CSM is in the INS_ACTIVE (bright green) State.
NOTE
MCC Cards will not enable without the CSM being INS.
4 Verify that the 19.6608 MHz CSM Clock is present; MCC Cards will not enable without it.
S If MCC Cards give “invalid or no System Time,” proceed to Step 5.
NOTE
BBX Cards should not be enabled for ATP Tests.
5 Verify that the CSM is enabled.
6 When all else fails, perform the following actions.
6a Log out of the BTS.
6b Exit the LMF.
table continued on next page
6