FEB 2005 1X SC 4812T Lite BTS Optimization/ATP 6-9
PRELIMINARY
Troubleshooting: Download
Table 6-8: Code Download Failure Troubleshooting Procedure
n Step Action
1 Verify that the T1 or E1 Span is disconnected from the BTS at Site I/O Boards.
Refer to Figure 3-2.
2 Verify that the LMF can communicate with the BTS Devices using the LMF Status Function.
3 Establish communications with the MGLI before trying to communicate with any other BTS
Device.
The MGLI must be INS_ACTIVE (bright green).
4 Verify that the target card is physically present in the cage and powered-up.
S If the target card LED is solid red, it implies a hardware failure.
S If the target card LED is bright green, proceed to Step 9.
5 Reset the target card by re-seating it.
S If the LED Alarm is still being reported, proceed to Step 6.
S If the LED Alarm is no longer being reported, proceed to Step 9.
6 Replace with the same type of card from another slot and retry.
7 Re-seat the card and try again.
S If the Download Portion completes and the Reset Portion fails, proceed to Step 8.
S If a BBX or an MCC remains OOS_ROM (blue) after Code Download, proceed to Step 9.
S If a BBX reports a Failure Message and is OOS_RAM, the Code Load was OK.
Use the LMF Status Function to verify the Load.
8 Reset the device by selecting the device and selecting Reset.
9 Use the LMF Device > Status Function to verify that the Code Load was accepted.
S If the Code Load was accepted, proceed to Step 10.
S If the Code Load was not accepted, proceed to Table 6-9 to troubleshoot the Data Download
Failure.
10 Use LMF Device > Download > Flash to load RAM Code into Flash Memory.
6