User's Manual
Table Of Contents
- Chapter 4: Acceptance Test Procedures
- Automated Acceptance Test Procedure
- Acceptance Tests - Test Set-up
- Abbreviated (All-inclusive) Acceptance Tests
- Individual Acceptance Tests
- TX Spectral Purity Transmit Mask Acceptance Test
- TX Waveform Quality (Rho) Acceptance Test
- TX Pilot Time Offset Acceptance Test
- TX Code Domain Power/Noise Floor Acceptance Test
- RX FER Acceptance Test
- Generating an ATP Report
- Updating Calibration Data Files
- Chapter 5: Prepare to Leave the Site
- Chapter 6: Troubleshooting
- Basic Troubleshooting: Overview
- Troubleshooting: Installation
- Cannot Log into Cell-Site
- Force LAN A Active (LMF Connection at I/O Panel LAN Connector)
- Force LAN A Active (LMF Connection at Service Shelf LAN Connector)
- Set the GLI IP Address
- Cannot Communicate with Power Meter
- Cannot Communicate with Communications System Analyzer
- Cannot Communicate with Signal Generator
- Troubleshooting: Download
- Troubleshooting: Calibration
- Basic Troubleshooting: RF Path Fault Isolation
- Troubleshooting: Transmit ATP
- Troubleshooting: Receive ATP
- Troubleshooting: CSM Checklist
- Troubleshooting: SCCP Backplane
- Troubleshooting: RFDS
- Module Front Panel LED Indicators and Connectors
- Troubleshooting: Span Control Link
- Appendix A: Data Sheets
- Appendix B: PN Offset/I & Q Offset Register Programming Information
- Appendix C: FRU Optimization / ATP Test Matrix
- Appendix D: BBX Gain Set Point vs. BTS Output
- Appendix E: CDMA Operating Frequency Programming Information
- Appendix F: Test Equipment Preparation
- Test Equipment Preparation
- Verifying and Setting GPIB Addresses
- Agilent E4406A Transmitter Tester GPIB Address
- Agilent E4432B Signal Generator GPIB Address
- Advantest R3267 Spectrum Analyzer GPIB Address
- Advantest R3562 Signal Generator GPIB Address
- Agilent 8935 Series E6380 (formerly HP 8935) Test Set GPIB Address
- Hewlett Packard HP 8921A and HP83236A/B GPIB Address
- Advantest R3465 Communications Test Set GPIB Address
- Motorola CyberTest GPIB Address
- HP 437 Power Meter GPIB Address
- Gigatronics 8541C Power Meter GPIB Address
- RS232 GPIB Interface Adapter
- Test Equipment Inter-Unit Connection, Testing, and Control
- Inter-Unit Connection, Testing, and Control Settings
- HP 8921A with PCS Interface Test Equipment Connections
- HP 8921A with PCS Interface System Connectivity Test
- Pretest Set-up for HP 8921A
- Pretest Set-up for Agilent 8935
- Advantest R3465 Connection
- R3465 GPIB Clock Set-up
- Pretest Set-up for Advantest R3465
- Agilent 8932/E4432B Test Equipment Interconnection
- Agilent E4406A/E4432B Test Equipment Interconnection
- Advantest R3267/R3562 Test Equipment Interconnection
- Equipment Calibration
- Manual Cable Calibration
- Appendix G: Downloading ROM Code
- Appendix H: In-Service Calibration
- Appendix I: Packet Backhaul Configuration
- BTS Router Initial Configuration
- Terminal Setup
- Downloading Minimum Canned BTS Router Configuration Files
- Verifying IOS Canned Version of the CF Memory Card
- Replacing Installed BTS Router CF Memory Card IOS Version
- Background
- Equipment and Software Required for Verification Methods
- Required Publications
- Method 1: Replacement of Installed Router CF Card IOS Data
- Method 2: Using a CF Memory Card Reader for Replacement of Installed IOS Version and Changing File Sequence ...
- Change CF Memory Card File Sequence to Place IOS File First on the Card
- Verify and Upgrade ROMMON Version
- Recovery from BTS Router Boot to ROMMON
- Entering or Changing Router FE Interface IP Address
- Preparation for Site Turn-over
- Index
Prepare to Leave the Site – continued
FEB 2005 1X SC 4812T Lite BTS Optimization/ATP 5-7
PRELIMINARY
Table 5-6: Circuit Backhaul Remote Reset and Initialization Procedure
n ActionStep
10 Once the GLI Cards are loaded with the specified Code Version, the active GLI will verify and
update, as required, its RAM.
– Also, if necessary, ROM Code Loads for the installed CSM, MCC, and BBX Cards using the
DLM.
11 After all activities at the site have been completed, contact the OMC–R to confirm that the BTS is
under OMC–R control.
Packet Backhaul Remote Reset and Initialization
Perform the procedure in Table 5-7 to remotely reset the BTS Devices in
a Packet Backhaul BTS, and then remotely initialize the same BTS.
Table 5-7: Packet Backhaul Remote Reset and Initialization Procedure
n Step Action
1 Terminate the LMF Session by performing the procedure in Table 5-3.
2 Reconnect the Spans by performing the procedure in Table 5-4.
3 Determine which of the two types of PREACTIVATE Load Processes is applicable to your
situation.
Rolling Upgrade: This Load Process is only available when the BTS Cards are populated for Full
Redundancy as applicable.
Quick Reboot: This Load Process is used when Redundancy for the BTS Cards is not available.
– The GLI3 disables and reboots to the new Load. This will cause all the other cards to go out
of service.
– Once it is rebooted, the GLI3 determines which cards require a new Load and then downloads
the cards in the order that they establish communication with the GLI3 following their reboot.
– The GLI3 can reload up to 16 devices simultaneously.
4 From the BTS Site, contact the OMC–R and request the operator to PREACTIVATE the BTS to
the required software version for the BSS.
5 After all activities at the site have been completed, contact the OMC–R to confirm that the BTS is
under OMC–R control.
5