Prepare to Leave the Site – continued
5-4 1X SC 4812T Lite BTS Optimization/ATP FEB 2005
PRELIMINARY
Table 5-2: Bring Modules into Service Procedure
n ActionStep
3 Click on Device in the BTS Menu Bar, and select Enable from the Pull–down Menu.
A Status Report Window is displayed.
* IMPORTANT
If a BBX is selected, a Transceiver Parameters Window is displayed to collect Keying
Information. Do not enable the BBX.
4 Click Cancel to close the Transceiver Parameters Window, if applicable.
5 Click OK to close the Status Report Window.
Bright Green is the color of devices that successfully change to INS.
LMF Removal
Perform the procedure in Table 5-3 as required to terminate the LMF
GUI Session and remove the LMF Computer.
Table 5-3: Terminate the LMF Session and Remove the LMF Procedure
n Step Action
! CAUTION
Do not power down the LMF Computer without performing the procedure below; corrupted
and/or lost Data Files may result.
1 Log out of all BTS Sessions and exit the LMF by clicking on File in the LMF Window Menu Bar
and selecting Logout and Exit from the Pull–down Menu.
2 In the Windows Task Bar, click Start and select Shutdown.
3 Click Yes when the Shut Down Windows Message appears.
4 Wait for the system to shut down and the screen to go blank.
5 Disconnect the LMF Computer Ethernet Port from the BTS Frame.
6 Disconnect the LMF Computer Serial Port, the RS–232–to–GPIB Interface Box, and the GPIB
Cables as required for equipment transport.
5