Prepare to Leave the Site
FEB 2005 1X SC 4812T Lite BTS Optimization/ATP 5-3
PRELIMINARY
External Test Equipment
Removal
Perform the procedure in Table 5-1 to disconnect the Test Equipment and
configure the BTS for active service.
Table 5-1: External Test Equipment Removal Procedure
n Step Action
n WARNING
Make sure that no BBX Cards are keyed before performing this procedure.
Failure to do so can result in personal injury and damage to BTS LPA Modules.
1 At the rear of the frame, disconnect all external Test Equipment from all TX and RX Connectors.
2 Reconnect and visually inspect all TX and RX Antenna Feed Lines at the Frame RF Interface
Panel.
* IMPORTANT
Verify that all Sector Antenna Feed Lines are connected to the correct Antenna Connectors on the
frame. Crossed Antenna Cables will degrade Call Processing.
Bringing Modules into Service
with the LMF
Whenever possible, have the CBSC/MM bring up the site
and enable all devices on the BTS.
NOTE
If a Reason Code is present and/or data should/could not be loaded
remotely from the CBSC, follow the steps outlined in Table 5-2 as
required to bring BTS Processor Modules from an OOS State to an INS
State.
Table 5-2: Bring Modules into Service Procedure
n Step Action
1 In the LMF GUI Environment, select the device(s) to be enabled by clicking on each one.
* IMPORTANT
S The MGLI and CSM must be INS_ACTIVE (bright green) before an MCC can be enabled.
2 Enable the Processor Cards in the following order.
1. MGLI
2. CSM Cards
3. MCC Cards
table continued on next page
5