User's Manual
Table Of Contents
- Chapter 4: Acceptance Test Procedures
- Automated Acceptance Test Procedure
- Acceptance Tests - Test Set-up
- Abbreviated (All-inclusive) Acceptance Tests
- Individual Acceptance Tests
- TX Spectral Purity Transmit Mask Acceptance Test
- TX Waveform Quality (Rho) Acceptance Test
- TX Pilot Time Offset Acceptance Test
- TX Code Domain Power/Noise Floor Acceptance Test
- RX FER Acceptance Test
- Generating an ATP Report
- Updating Calibration Data Files
- Chapter 5: Prepare to Leave the Site
- Chapter 6: Troubleshooting
- Basic Troubleshooting: Overview
- Troubleshooting: Installation
- Cannot Log into Cell-Site
- Force LAN A Active (LMF Connection at I/O Panel LAN Connector)
- Force LAN A Active (LMF Connection at Service Shelf LAN Connector)
- Set the GLI IP Address
- Cannot Communicate with Power Meter
- Cannot Communicate with Communications System Analyzer
- Cannot Communicate with Signal Generator
- Troubleshooting: Download
- Troubleshooting: Calibration
- Basic Troubleshooting: RF Path Fault Isolation
- Troubleshooting: Transmit ATP
- Troubleshooting: Receive ATP
- Troubleshooting: CSM Checklist
- Troubleshooting: SCCP Backplane
- Troubleshooting: RFDS
- Module Front Panel LED Indicators and Connectors
- Troubleshooting: Span Control Link
- Appendix A: Data Sheets
- Appendix B: PN Offset/I & Q Offset Register Programming Information
- Appendix C: FRU Optimization / ATP Test Matrix
- Appendix D: BBX Gain Set Point vs. BTS Output
- Appendix E: CDMA Operating Frequency Programming Information
- Appendix F: Test Equipment Preparation
- Test Equipment Preparation
- Verifying and Setting GPIB Addresses
- Agilent E4406A Transmitter Tester GPIB Address
- Agilent E4432B Signal Generator GPIB Address
- Advantest R3267 Spectrum Analyzer GPIB Address
- Advantest R3562 Signal Generator GPIB Address
- Agilent 8935 Series E6380 (formerly HP 8935) Test Set GPIB Address
- Hewlett Packard HP 8921A and HP83236A/B GPIB Address
- Advantest R3465 Communications Test Set GPIB Address
- Motorola CyberTest GPIB Address
- HP 437 Power Meter GPIB Address
- Gigatronics 8541C Power Meter GPIB Address
- RS232 GPIB Interface Adapter
- Test Equipment Inter-Unit Connection, Testing, and Control
- Inter-Unit Connection, Testing, and Control Settings
- HP 8921A with PCS Interface Test Equipment Connections
- HP 8921A with PCS Interface System Connectivity Test
- Pretest Set-up for HP 8921A
- Pretest Set-up for Agilent 8935
- Advantest R3465 Connection
- R3465 GPIB Clock Set-up
- Pretest Set-up for Advantest R3465
- Agilent 8932/E4432B Test Equipment Interconnection
- Agilent E4406A/E4432B Test Equipment Interconnection
- Advantest R3267/R3562 Test Equipment Interconnection
- Equipment Calibration
- Manual Cable Calibration
- Appendix G: Downloading ROM Code
- Appendix H: In-Service Calibration
- Appendix I: Packet Backhaul Configuration
- BTS Router Initial Configuration
- Terminal Setup
- Downloading Minimum Canned BTS Router Configuration Files
- Verifying IOS Canned Version of the CF Memory Card
- Replacing Installed BTS Router CF Memory Card IOS Version
- Background
- Equipment and Software Required for Verification Methods
- Required Publications
- Method 1: Replacement of Installed Router CF Card IOS Data
- Method 2: Using a CF Memory Card Reader for Replacement of Installed IOS Version and Changing File Sequence ...
- Change CF Memory Card File Sequence to Place IOS File First on the Card
- Verify and Upgrade ROMMON Version
- Recovery from BTS Router Boot to ROMMON
- Entering or Changing Router FE Interface IP Address
- Preparation for Site Turn-over
- Index
Power Delta Calibration – continued
H-18 1X SC 4812T Lite BTS Optimization/ATP FEB 2005
PRELIMINARY
Table H-5: Advantest Power Delta Calibration Procedure
n ActionStep
15 Connect the RF Cable from the R3561L Signal Generator RF OUT Port to the R3465 INPUT Port.
– Refer to Figure H-10.
16 Press the Output CRT Menu Key to change the Output to ON.
17 Press the CW Key in the MEASUREMENT Area of the Control Panel.
18 Press the LEVEL Key in the ENTRY Area of the Control Panel.
19 Set the REF LEVEL to 10 dBm using the Keypad Entry Keys.
20 Press the dB/div CRT Menu Key.
21 Press the 10 dB/div CRT Menu Key.
22 Press the FREQ Key in ENTRY Area of the Control Panel.
23 Set the frequency to the desired value using the Keypad Entry Keys.
24 Press the more 1/2 CRT Menu Key.
25 Press the Preselector CRT Menu Key to highlight 3.0G.
26 Press the FORMAT Key in the Display Control area of the Control Panel.
27 Press the TRACE CRT Menu Key.
28 Press the AVG A CRT Menu Key.
29 Set AVG to 20 using Keypad Entry Keys.
30 Press the return CRT Menu Key.
31 Press the SPAN Key in the ENTRY Area of the Control Panel.
32 Press the Zero Span CRT Menu Key.
33 Press the BW Key in the ENTRY Area of the Control Panel.
34 Press the RBW CRT Menu Key to highlight MNL. using Keypad Entry Keys enter 30 kHz.
35 Set RBW to 30 kHz using Keypad Entry Keys.
36 Press the VBW CRT Menu Key to highlight MNL.
37 Set VBW to 1 MHz using Keypad Entry Keys.
38 Press the Marker ON Key in the Display Control area of the Control Panel.
table continued on next page
H