Power Delta Calibration – continued
H-18 1X SC 4812T Lite BTS Optimization/ATP FEB 2005
PRELIMINARY
Table H-5: Advantest Power Delta Calibration Procedure
n ActionStep
15 Connect the RF Cable from the R3561L Signal Generator RF OUT Port to the R3465 INPUT Port.
Refer to Figure H-10.
16 Press the Output CRT Menu Key to change the Output to ON.
17 Press the CW Key in the MEASUREMENT Area of the Control Panel.
18 Press the LEVEL Key in the ENTRY Area of the Control Panel.
19 Set the REF LEVEL to 10 dBm using the Keypad Entry Keys.
20 Press the dB/div CRT Menu Key.
21 Press the 10 dB/div CRT Menu Key.
22 Press the FREQ Key in ENTRY Area of the Control Panel.
23 Set the frequency to the desired value using the Keypad Entry Keys.
24 Press the more 1/2 CRT Menu Key.
25 Press the Preselector CRT Menu Key to highlight 3.0G.
26 Press the FORMAT Key in the Display Control area of the Control Panel.
27 Press the TRACE CRT Menu Key.
28 Press the AVG A CRT Menu Key.
29 Set AVG to 20 using Keypad Entry Keys.
30 Press the return CRT Menu Key.
31 Press the SPAN Key in the ENTRY Area of the Control Panel.
32 Press the Zero Span CRT Menu Key.
33 Press the BW Key in the ENTRY Area of the Control Panel.
34 Press the RBW CRT Menu Key to highlight MNL. using Keypad Entry Keys enter 30 kHz.
35 Set RBW to 30 kHz using Keypad Entry Keys.
36 Press the VBW CRT Menu Key to highlight MNL.
37 Set VBW to 1 MHz using Keypad Entry Keys.
38 Press the Marker ON Key in the Display Control area of the Control Panel.
table continued on next page
H