Power Delta Calibration – continued
FEB 2005 1X SC 4812T Lite BTS Optimization/ATP H-17
PRELIMINARY
Advantest R3465 Power Delta
Calibration
Use the Advantest R3465 Spectrum Analyzer to measure power during
ISC only for IS–95A and B Operation. After the Offset Value has been
calculated, add it to the TX Test Cable Insertion Loss Value.
Perform the procedure in Table H-5 to perform the Advantest 3465
Power Delta Calibration Procedure.
Table H-5: Advantest Power Delta Calibration Procedure
n Step Action
NOTE
Perform this procedure after Test Equipment has been allowed to warm–up and stabilize for a
minimum of 60 minutes.
After it is warmed–up and stabilized, calibrate the Test Equipment as described in the “Test
Set Calibration” section of Chapter 3.
1 Press the SHIFT and the PRESET Keys located below the CRT Display.
2 Press the ADVANCE Key in the MEASUREMENT Area of the Control Panel.
3 Press the CDMA Sig CRT Menu Key.
4 Press the FREQ Key in the ENTRY Area of the Control Panel.
5 Set the frequency to the desired value using the Keypad Entry Keys.
6 Press the LEVEL Key in the ENTRY Area of the Control Panel.
7 Set the LEVEL to 0 dBm using the Keypad Entry Keys.
8 Verify that the Mod CRT Menu Key highlighting is OFF.
If it is highlighted, press the Mod Key to toggle it OFF.
9 Verify that the Output CRT Menu Key highlighting is OFF,
If it is highlighted, press the Output Key to toggle it OFF.
10 Zero the Power Meter prior to connecting the Power Sensor to the RF Cable from the Signal
Generator.
NOTE
For best accuracy, always re–Zero the Power Meter before connecting the Power Sensor to the
component being calibrated.
11 Connect the RF Cable from the R3561L CDMA Signal Generator RF OUT Port to the Power Sensor.
Refer to Figure H-9.
12 Press the Output CRT Menu Key to toggle the Output to ON.
13 Record the Power Meter Reading as Result A.
A________________________.
14 Press the Output CRT Menu Key to toggle the Output to OFF.
table continued on next page
H