User's Manual

Table Of Contents
Power Delta Calibration – continued
FEB 2005 1X SC 4812T Lite BTS Optimization/ATP H-15
PRELIMINARY
Table H-4: HP 8921A Power Delta Calibration Procedure
n ActionStep
7 Connect the short RF Cable between the source HP 8921A Duplex Out Port and the measuring
HP 8921A RF–IN Port.
Refer to Figure H-8.
8 Ensure that the source HP 8921A Settings are the same as in Step 3.
9 Set the measuring HP 8921A as follows:
Measure Mode to CDMA Anl
Frequency to the CDMA Calibration Target Frequency
Input Attenuation to 0 dB
Input Port to RF–IN
Gain to Auto
Analyzer Direction to Fwd
10 Turn on the source HP 8921A Signal Output.
11 Measure and record the Channel Power Reading on the measuring HP 8921A as Result B.
B ________________________
12 Turn off the source HP 8921A Signal Output and disconnect the equipment.
13 Compute the Delta between HP437 and HP 8921A using the following formula.
Delta = A – B
Example: Delta = –0.70 dBm – (–1.25 dBm) = 0.55 dBm
Example: Delta = 0.26 dBm – 0.55 dBm = –0.29 dBm
NOTE
These examples are included to show the mathematics and do not represent actual readings.
NOTE
Add this Delta Value to the TX Cable Loss Value during In–Service Calibration.
Refer to Step 4 in Table H-6.
Short RF Cable
HP 8921A
DUPLEX
OUT
HP437B
Power
Sensor
SENSOR
FW00801
Figure H-7: Delta Calibration Set–up – HP 8921A to HP437
H