Power Delta Calibration – continued
H-4 1X SC 4812T Lite BTS Optimization/ATP FEB 2005
PRELIMINARY
Table H-1: Agilent E4406A Power Delta Calibration Procedure
n ActionStep
2 Ensure that the E4406A and E4432B are connected as shown in Figure F-18.
3 Connect a short RF Cable from the E4432B RF OUTPUT Connector the HP437 Power Meter
Power Sensor.
Refer to Figure H-1.
4 Set the E4432B Signal Generator by performing the following actions.
4a Press Preset to exit any modes for which the Signal Generator is configured.
4b Press Frequency and enter the frequency of the channel to be calibrated on the Numeric Keypad.
4c Using the Softkeys to the right of the screen, select the Frequency Range to be measured; for
example: MHz.
4d Press Amplitude and, using the Numeric Keypad, set the Signal Amplitude to 0 (zero).
4e Using the Softkeys, set the measurement type to dBm.
5 On the E4432B, press RF On/Off to toggle the RF Output to RF ON.
Note that the RF On/Off Status in the Screen Display changes.
6 Measure and record the Value Reading on the HP437 Power Meter as result.
A____________________
7 On the E4432B, press RF On/Off to toggle the RF Output to RF OFF.
Note that the RF On/Off Status in the Screen Display changes.
8 Disconnect the short RF Cable from the HP437 Power Meter Power Sensor, and connect it to the
RF INPUT Connector on the E4406A Transmitter Tester.
Refer to Figure H-2.
* IMPORTANT
Do not change the Frequency and Amplitude Settings on the E4432B when performing the
following actions.
9 Set the E4406A by performing the following actions.
9a Press Preset to exit any modes for which the Transmitter Tester is configured.
9b Press MODE and, using the Softkeys to the right of the screen, select cdmaOne.
9c Press MEASURE and, using the Softkeys, select spectrum.
9d Press Frequency and, using the Softkeys, select Center Frequency.
9e Enter the frequency of the channel to be calibrated using the Numeric Keypad.
9f Using the Softkeys, select the Frequency Range to be measured; for example, MHz.
9g Press Input/Output and, using the Softkeys, select Input Atten.
9h Using the Numeric Keypad, set Input Atten to 0 (zero) and, using the Softkeys, select dB.
table continued on next page