Manual Cable Calibration
FEB 2005 1X SC 4812T Lite BTS Optimization/ATP F-35
PRELIMINARY
Calibrating the Test Cable
Set–up using HP PCS Interface
(HP83236)
Table F-23 covers the procedure to calibrate the Test Equipment using
the HP8921 Cellular Communications Analyzer equipped with the
HP83236 PCS Interface.
This calibration method must be executed with great care.
Some Losses are measured close to the minimum limit of
the Power Meter Sensor (–30dBm).
NOTE
Prerequisites
Ensure the following prerequisites have been met before proceeding:
S Test Equipment to be calibrated has been connected correctly for
Cable Calibration.
S Test Equipment has been selected and calibrated.
Table F-23: Test Cable Set–up (using the HP PCS Interface) Calibration Procedure
n Step Action
NOTE
Verify that GPIB Controller is turned off.
1 Insert the HP83236 Manual Control System Card into the Memory Card Slot.
2 Press the Preset Pushbutton.
3 Under Screen Controls, press the TESTS Pushbutton to display the TESTS (Main Menu) Screen.
2 Position the cursor on Select Procedure Location and select it.
3 In the Choices Selection Box, select CARD.
4 Position the cursor on Select Procedure Filename and select it.
5 In the Choices Selection Box, select MANUAL.
6 Position the cursor on RUN TEST and select it.
The HP Analyzer must be in Control Mode.
7 Select YES.
8 Proceed based upon the analyzer being used.
S If the HP83236A is being used, proceed to Step 9.
S If the HP83236B is being used, proceed to Step 10.
table continued on next page