F-30 1X SC 4812T Lite BTS Optimization/ATP FEB 2005
PRELIMINARY
Calibration Without the LMF
Several Test Equipment Items used in the Optimization Process require
Pre–Calibration actions or Calibration Verification that are not supported
by the LMF. Procedures to perform these activities for the applicable
Test Equipment Items are covered in this section.
Agilent E4406A Transmitter
Tester Self–alignment
(Calibration)
System Key
Softkey Buttons
Softkey Label Display Area
Figure F-20: Performing Agilent E4406A Self–alignment (Calibration)
Refer to Figure F-20 and perform the procedure in Table F-20 to perform
the Agilent E4406A Self–alignment (Calibration).
Table F-20: Agilent E4406A Self–alignment (Calibration) Procedure
n Step Action
1 In the SYSTEM section of the Instrument Front Panel, press the System Key.
The Softkey Labels displayed on the right side of the instrument screen changes.
2 Press the Alignments Softkey Button to the right of the instrument screen.
The Softkey Labels changes.
3 Press the Align All Now Softkey Button.
All other instrument functions will be suspended during the alignment.
The display changes to show progress and results of the alignments performed.
The alignment will take less than one minute.