User's Manual

Table Of Contents
Test Equipment Inter–Unit Connection, Testing, and Control – continued
F-28 1X SC 4812T Lite BTS Optimization/ATP FEB 2005
PRELIMINARY
Agilent E4406A/E4432B Test
Equipment Interconnection
To provide proper operation during testing when both units are required,
the 10 MHz Reference Signal from the E4406A Transmitter Test Set
must be provided to the E4432B Signal Generator.
Connect a BNC (M)–BNC (M) Cable from the E4406A 10 MHz
OUT (SWITCHED) Connector to the E4432B 10MHz IN
Connector as shown in Figure F-18.
E4406A
10 MHz OUT
(SWITCHED)
E4432B
10 MHz IN
TO GPIB BOX
TDME0009–1
Figure F-18: Agilent 10 MHz Reference Connections
F