Test Equipment Inter–Unit Connection, Testing, and Control – continued
F-26 1X SC 4812T Lite BTS Optimization/ATP FEB 2005
PRELIMINARY
R3465 GPIB Clock Set–up
Table F-18 describes the steps to set the clock for the Advantest R3465
Equipment.
Table F-18: Advantest R3465 Clock Set–up Procedure
n Step Action
1 Observe the current date and time displayed in upper right of the CRT Display.
2 If the date and time are incorrect, perform the following to change them:
2a Push the Date/Time CRT Menu Key.
2b Rotate the Vernier Knob to select and set.
2c Push the Vernier Knob to enter.
2d Press the SHIFT Button, then press the PRESET Button (just below the CRT Display).
Pretest Set–up for Advantest
R3465
Before the Advantest R3465 Analyzer is used for LMF–controlled
testing, it must be set–up correctly for automatic testing.
Table F-19: Pretest Set–up for Advantest R346
n Step Action
1 Press the SHIFT Button so the LED next to it is illuminated.
2 Press the RESET Button.