Test Equipment Inter–Unit Connection, Testing, and Control – continued
FEB 2005 1X SC 4812T Lite BTS Optimization/ATP F-23
PRELIMINARY
Pretest Set–up for HP 8921A
Before the HP 8921A CDMA Analyzer is used for LMF–controlled
testing, it must be set–up correctly for automatic testing.
Table F-16: Pretest Set–up for HP 8921A
n Step Action
1 Unplug the Memory Card if it is plugged in.
2 Press the CURSOR CONTROL Knob.
3 Position the cursor on IO CONFIG (under To Screen and More) and select it.
4 Select Mode and set for Talk&Lstn.
Pretest Set–up for Agilent 8935
Before the Agilent 8935 Analyzer is used for LMF–controlled testing, it
must be set–up correctly for automatic testing.
Table F-17: Pretest Set–up for Agilent 8935
n Step Action
1 Unplug the Memory Card if it is plugged in.
2 Press the Shift Button and then press the I/O Config Button.
3 Press the Push to Select Knob.
4 Position the cursor on IO CONFIG and select it.
5 Select Mode and set for Talk&Lstn.