User's Manual

Table Of Contents
Verifying and Setting GPIB Addresses – continued
F-16 1X SC 4812T Lite BTS Optimization/ATP FEB 2005
PRELIMINARY
HP 437 Power Meter GPIB
Address
Refer to Figure F-10 and follow the steps in Table F-11 to verify and, if
necessary, change the HP 437 GPIB Address.
Enter
Preset
SHIFT (BLUE) PUSHBUTTON –
ACCESSES FUNCTION AND
DATA ENTRY KEYS IDENTIFIED
WITH LIGHT BLUE TEXT ON
THE FRONT PANEL ABOVE
THE BUTTONS
FW00308REF
Figure F-10: HP 437 Power Meter
This procedure assumes that the Test Equipment is set–up
and ready for testing.
NOTE
Table F-11: Verify and/or Change the HP 437 Power Meter GPIB Address Procedure
n Step Action
1 Press Shift and PRESET.
2 Use the y (UP) Arrow Key to navigate to the HP–IB ADRS and press ENTER.
The HP–IB Address is displayed.
NOTE
HP–IB is the same as GPIB.
3 If the current GPIB Address is not set to 13, perform the following actions to change it.
3a Use the y (UP) and b (DOWN) Arrow Keys to change the HP–IB ADRS to 13.
3b Press ENTER to set the new address.
4 Press Shift and ENTER to return to a standard configuration.