User's Manual

Table Of Contents
Verifying and Setting GPIB Addresses – continued
FEB 2005 1X SC 4812T Lite BTS Optimization/ATP F-15
PRELIMINARY
Motorola CyberTest GPIB
Address
Perform the procedure in Table F-10 to verify and, if necessary, change
the GPIB Address on the Motorola CyberTest. Changing the GPIB
Address requires the following items:
S Motorola CyberTest Communications Analyzer.
S Computer running Windows 3.1/Windows 95 (or later).
S Motorola CyberTAME Software Program named “TAME”.
S Parallel Printer Port Cable (shipped with the CyberTest unit).
This procedure assumes that the Test Equipment is set–up
and ready for testing.
NOTE
Table F-10: Verify and/or Change Motorola CyberTest GPIB Address Procedure
n Step Action
1 On the LMF Desktop, locate the CyberTAME Icon.
2 Double–click on the CyberTAME Icon to run the CyberTAME Application.
3 In the CyberTAME Window Taskbar, under Special, select IEEE.488.2.
The CyberTAME Software will query the CyberTest Analyzer for its current GPIB Address.
It then will open the IEEE 488.2 Dialog Box.
4 If the current GPIB Address is not 18, perform the following actions to change it.
4a Set the GPIB Address to 18.
Use the UP and DOWN Increment Arrows.
or
Double–click in the field and type the number.
4b Click on the OK Button.
The new address will be written to the CyberTest through the Parallel Port and saved.
5 Verify that the address has been set by repeating Steps 3 and 4.
The new address should now appear in the IEEE 488.2 Dialog Box Address Field.
F