User's Manual

Table Of Contents
Verifying and Setting GPIB Addresses – continued
F-14 1X SC 4812T Lite BTS Optimization/ATP FEB 2005
PRELIMINARY
Advantest R3465
Communications Test Set GPIB
Address
Refer to Figure F-9 and perform the procedure in Table F-9 to verify
and, if necessary, change the GPIB Address for the Advantest R3465.
BNC
“T”
REF UNLOCK
EVEN
SEC/SYNC IN
CDMA
TIME BASE IN
POWER
OFF
ON
REF FW00337
LCL Shift Preset
GPIB and others
Vernier
Knob
Figure F-9: R3465 Communications Test Set
This procedure assumes that the Test Equipment is set–up
and ready for testing.
NOTE
Table F-9: Verify and/or Change Advantest R3465 GPIB Address Procedure
n Step Action
1 To verify that the GPIB Address is set correctly, perform the following:
1a Press SHIFT then PRESET.
1b Press LCL.
1c Press the GPIB and Others CRT Menu Key to view the current address.
2 If the current GPIB Address is not set to 18, perform the following actions to change it.
2a Turn the Vernier Knob as required to select 18.
2b Press the Vernier Knob to set the address.
3 To return to normal operation, press Shift and Preset.
F