User's Manual

Table Of Contents
Verifying and Setting GPIB Addresses – continued
FEB 2005 1X SC 4812T Lite BTS Optimization/ATP F-9
PRELIMINARY
Table F-6: Verify that and Change Advantest R3267 GPIB Address
n ActionStep
3b
Enter 18 on the Keypad in the ENTRY Section of the Instrument Front Panel.
Characters typed on the Keypad will replace the address displayed in the GPIB Address
Entry Window.
NOTE
To correct an entry, press the BS (Backspace) Key at the lower right of the Keypad to delete one
character at a time.
3c Press the ENTR Key to the lower right of the Keypad to set the new GPIB Address.
The GPIB Address Entry window closes.
The new address is displayed in the bottom portion of the GPIB Address Softkey Label.
Advantest R3562 Signal
Generator GPIB Address
Set the GP–IP ADDRESS Switch on the rear of the Advantest R3562
Signal Generator to Address 1 as shown in Figure F-6.
12345678
54321
GP–IP ADDRESS
1
0
GPIB Address set to “1”
Figure F-6: Advantest R3562 GPIB Address Switch Setting
F