User's Manual

Table Of Contents
Test Equipment Preparation – continued
F-2 1X SC 4812T Lite BTS Optimization/ATP FEB 2005
PRELIMINARY
Connections
It is recommended that you use a hub with BNC and RJ–45
Connections. Suggested Models: Netgear Model EN104 (4 Port) or
EN108 (8 Port).
Do NOT use Model Numbers ending with “TP”; those
have no BNC Connectors.
IMPORTANT
*
The LMF connects to the hub, which in turn, connects to the BTS and to
the Agilent E7495A.
Agilent E7495A to Hub – This is an Ethernet Cable, RJ–45 to RJ–45.
LMF to Hub – Use one of the following cables to connect the LMF to
the Hub:
Ethernet Cable, RJ–45 to RJ–45 – Make sure that the LAN Card is
set for either AUTO or to use RJ–45 only.
COAX Cable between LAN Card and Hub – Use a “T” on the hub
and connect a cable between the other end of the “T” and the BTS
LAN Connection.
Hub to BTS – Use BNC “T” Connector on the hub. If your hub doesn’t
have BNC Ports, use a BNC to UTP Adapter.
Detecting Test Equipment
Check that no other equipment is connected to the LMF. Agilent
equipment must be connected to the LAN to detect it. Then perform the
procedures described in Table F-2.
Table F-2: Agilent E7495A Test Equipment Detection Procedure
n Step Action
1 Click the Tools Menu.
2 Choose Options.
3 Check Agilent E7495A Option in non–GPIB Test Equipment and enter its IP Address.
4 Click Apply and wait a moment.
5 Click Dismiss.
F